Strive to Improve Medical Conditions, Reduce Health Care Costs.
9 Renmin Rd(E), Yangshe Town, Zhangjiagang City, Jiangsu Province, China.
+86 18913609266
Model:CBMPCR06A
Channel:2
Reaction per run:96
Block Format:96-well 0.2 ml
Color combinations:Up to 2
Light Source:High brightness monochrome LED
Detector:High sensitive cold light CCD
Detection dynamic range:10^2~10^10
Sensitivity:Down to 1 copy
Reaction volume:15ul -100ul
Order No.:MSLPCR06A
Model:CBMPCR06A
Channel:2
Reaction per run:96
Block Format:96-well 0.2 ml
Color combinations:Up to 2
Light Source:High brightness monochrome LED
Detector:High sensitive cold light CCD
Detection dynamic range:10^2~10^10
Sensitivity:Down to 1 copy
Reaction volume:15ul -100ul
Chemistry:all real-time PCR-based chmistries.Flexibility for chemistries with or without passive reference dye
Excitation source:White LED
Excitation filters/colors:Channel 1- 470nm; Channel 2- 525nm
Detection filters/colors:Channel 1- 525nm; Channel 2- 570nm
Kits & Reagent:Channel 1- FAM/SYBR; Channel 2- VIC/HEX/JOE/TET/TAMRA
Block Material:Peltier
Accuracy:≤±0.1℃
Uniformity:±0.4℃ (10 sec after reaching 95℃); ±0.2℃ (10 sec after reaching 55℃)
Temperature range :0-100℃
Max ramp rate:6℃
Gradient range :30-100℃
PC operation system:Windows XP/VISTA/Windows7/Windows8
MSLPCR06 operation system:Linus
CPU:A8
Communication:LAN/Wi-Fi
Multiple control:support
Application Available :Gene Expression,Genotyping,Copy Number Variation,Protein Detection,MicroRNA,Pathogen Detection
Dimension(L*W*H):592mm*440mm*280mm
Package dimension(L*W*H):840mm*710mm*530mm
Net Weight (Kg) :28.5
Gross Weight (Kg):60
Power Supply:
1.Standard configuration 220V/50HZ
2.Available upon special request 220V/60HZ,110V/60HZ,
3.Please note: Power supply is defaulted as standard configuration.Please remark on special request.Shipment date for special request might be later than standard configuration, please contact our salesperson to confirm.
Notice
Order No.:MSLPCR06B
Model:MSLPCR06B
Channel:5
Reaction per run:96
Block Format:96-well 0.2 ml
Color combinations:Up to 5
Light Source:High brightness monochrome LED
Detector:High sensitive cold light CCD
Detection dynamic range:10^2~10^10
Sensitivity:Down to 1 copy
Reaction volume:15ul -100ul
Chemistry:all real-time PCR-based chmistries. Flexibility for chemistries with or without passive reference dye
Excitation source:White LED
Excitation filters/colors:Channel 1- 470nm; Channel 2- 525nm; Channel 3- 585nm; Channel 4- 610nm
Detection filters/colors:Channel 1- 525nm; Channel 2- 570nm; Channel 3- 610nm; Channel 4- 678nm
Kits & Reagent:Channel 1- FAM/SYBR; Channel 2- VIC/HEX/JOE/TET/TAMRA; Channel 3- ROX/TEXRAD; Channel 4- CY5
Block Material:Peltier
Accuracy:≤±0.1℃
Uniformity:±0.4℃ (10 sec after reaching 95℃);±0.2℃ (10 sec after reaching 55℃)
Temperature range :0-100℃
Max ramp rate:6℃
Gradient range:30-100℃
PC operation system:Windows XP/VISTA/Windows7/Windows8
MSLPCR06 operation system:Linus
CPU:A8
Communication:LAN/Wi-Fi
Multiple control:Support
Application Available :Gene Expression,Genotyping,Copy Number Variation,Protein Detection,MicroRNA,Pathogen Detection
Dimension(L*W*H):592mm*440mm*280mm
Package dimension(L*W*H):840mm*710mm*530mm
Net Weight (Kg):28.7
Gross Weight (Kg):60
Power Supply:
1.Standard configuration 220V/50HZ
2.Available upon special request 220V/60HZ, 110V/60HZ
3.Please note: Power supply is defaulted as standard configuration. Please remark on special request. Shipment date for special request might be later than standard configuration, please contact our salesperson to confirm.
Notice